Experts in fire protection

Problem

Do you still have to do a round every day to check the functionality of your sprinkler system? Want to know more precisely what state your sprinkler system is in right now?

The directive VdS CEA 4001 requires daily monitoring of the functioning of the sprinkler system by its operator. There are various levels, operating pressures and other operating conditions to check and log. Without electrical monitoring, this means that every working day you have to look up each fitting to be checked - valuable time, which you can certainly use better doing other things!

In addition, many operators want more transparency with regard to maintenance due and the current state of the sprinkler system. Compliance with the maintenance schedule ensures its functioning and incidentally reduces your risk of liability. Information on its condition, such as runtimes of the auxiliary units, provides important warnings in good time on impending problems such as leaks. With MonitoringPlus you know more!

Solution

The FMZ 5000+ integrated fire alarm and extinguishing control panel provides all functionalities of electrical monitoring and of MonitoringPlus. If replacement of the sprinkler pump control cabinet is scheduled at the same time, these functionalities are ideally implemented with the electronic ESS 5000 M+ control cabinet. 

Shut-off valves whose incorrect settings could lead to faults are controlled via electrical monitoring. Filling levels, system pressures and other ambient- and operating conditions are continuously recorded. If there is a discrepancy from the target state, the FMZ 5000 M+ automatically displays the relevant fault and the nature of the problem. This saves long inspection rounds - a look at the display of the control panel will do!

The MonitoringPlus basic functions include the automatic display of maintenance due and special tests on the FMZ 5000 M+ plus operating hours- and event recording for compressors and nitrogen generators. More MonitoringPlus functions for even greater transparency can be optionally supplemented.

Scope of service

With retrofitting of the FMZ 5000 mod 4 M+

  • Dismantling as necessary of the existing fire detection control panel and/or fault detector
  • Installation of FMZ 5000 mod 4 M+ including wiring
  • Installation as necessary of the fault detector for position, pressure, level and temperature
  • If necessary, installation of compressor and nitrogen generator relays
  • Activation of the maintenance reminder function
  • Amending of the existing documentation and installation papers
  • Commissioning of the Monitoring(Plus) functions, function testing and briefing

Service Specifications

With retrofitting of the ESS 5000 M+ control cabinet

  • Decommissioning of the sprinkler system
  • Dismantling of the existing sprinkler pump control cabinet
  • Dismantling as necessary of the existing fire detection control panel and/or fault detector
  • Installation of ESS 5000 M + including wiring
  • Installation as necessary of the fault detector for position, pressure, level and temperature
  • Installation as necessary of the compressor and nitrogen generator relays
  • Activation of the maintenance reminder function
  • Amending of the existing documentation and installation papers
  • Recommissioning of the sprinkler system with Monitoring(Plus) functions, function testing and briefing