Experts in fire protection

Overview

Modern hospitals are complex systems: Lives are saved here; patients are treated and cared for – a stable organism with extensive vegetative functions. In the day-to-day life of a hospital, all staffing levels make sure that the hospital runs smoothly and that patient welfare is at the top of the agenda, as patients require rest, protection and help. The everyday life of a clinic is not immune to fires, but a targeted precautionary system does protect its key organs.

Hospitals these days, more than ever, therefore have to create a working environment where doctors, nurses and carers can focus on their core competencies. The structural design of a clinic is in this regard an important condition. Modern building services relieve and support employees in their work for patients. Modern fire protection provides an adequate technical framework so that staff and patients feel safe.

Flames, smoke, gas emissions, heat – fire has many facets. Minimax has the right fire detectors for all areas within a hospital. Their signals converge in the fire detection and extinguishing control panel, which issues an alarm to the people at risk and the fire brigade. In addition, the Minimax panel monitors the installed fire protection system for proper functioning and electrically triggers the extinguishing systems that are not equipped with their own triggering elements, e.g. sprinkler systems.

A sprinkler system ensures overall building protection in a hospital. Minimax offers a broad range of sprinkler types and special sprinklers that allow for ideal adaptation of the sprinkler system to the respective installation situation in the various protected areas.

Areas with special fire risks or deployment conditions require - either in addition to or instead of the sprinkler system - a tailored volume or local protection system. For this reason, deluge systems, Minifog water mist extinguishing systems, foam extinguishing systems, Oxeo inert gas extinguishing systems, halocarbon extinguishing systems and KS 2000 kitchen protection extinguishing systems are used in hospitals.

Structural fire protection, as well as technical systems by Minimax Mobile Services, such as fire extinguishers, wall hydrants and smoke and heat extraction systems, complete fire protection in hospitals.

Protected areas

1
Helicopter landing pads
2
Offices
3
Emergency power generators
4
Operating theaters/treatment rooms
5
Transformers
6
Waste disposal
7
Kitchens
8
Cable ducts
9
Server rooms
  1. Helicopter landing pads
    1 Helicopter landing pads

    Protection zone

    The well-being of patients in life-threatening conditions is at the center of an often hectic emergency ward. Rescuers, however, are also at risk.

    Risks

    • Used kerosene, hydraulic oil
    • Hot surfaces of the turbines
    • Rapid spread of fires

    Fire Protection

    Foam extinguishing systems with so-called monitors reliably extinguish fires on helicopter landing pads by covering burning liquids with an airtight and cooling layer of foam. 

  2. Offices
    2 Offices

    Protection zone

    Offices, conference rooms and dining rooms are generally used by staff and guests. In addition, staff members may also retire to break rooms or smoking rooms and to kitchens during work. Corridors run through the entire building, serving as a main traffic route.

    Risks

    • Defective electrical devices such as projectors and computers
    • Overheating of the lighting
    • Short circuits at vending machines

    Fire Protection

    Minifog EconAqua water mist extinguishing systems offer space- and water-saving protection and can be connected to an existing sprinkler system. In areas with higher ceilings, sprinkler systems provide reliable fire protection. 

  3. Emergency power generators
    3 Emergency power generators

    Protection zone

    Emergency generators are often housed in separate premises. During a power failure, these generators secure the power supply, maintain business operation and prevent financial loss due to an operational interruption.

    Risks

    • Diesel fuel, which ignites on hot surfaces
    • Leaking lubrication oil

    Fire Protection

    For local protection of the emergency generator, Minifog ProCon water mist extinguishing systems are ideal. These can be connected to the sprinkler systems installed for building protection purposes and fight fires quickly and effectively through open water mist nozzles. Minifog ProCon water mist extinguishing systems are triggered by a fire detection system that uses UniVario flame or heat detectors to detect fires.

  4. Operating theaters/treatment rooms
    4 Operating theaters/treatment rooms

    Protection zone

    The complex technology used in operating theaters also presents a risk of fire and malfunction:

    Risks

    • Kurzschlüsse in medizinischen Geräten
    • Ausfall gefährdet Menschen

    Fire Protection

    The sprinkler systems used for the protection of buildings also protect operating theaters and treatment rooms. Using Preaction sprinklers provides double protection. The extinguishing process starts only when both sprinklers open. In this way, areas with high-quality technical systems can be protected against unwanted water leakage and damage.

  5. Transformers
    5 Transformers

    Protection zone

    Transformers make sure that electricity is ready for network distribution. They function as links between the turbine, the turbine generators and the network. They consist typically of the transformer housing with a cooler, oil conservators and oil-filled insulators.

    Risks

    • Short circuits within the transformers
    • Overheating
    • Leaking oil

    Fire Protection

    As soon as overheating is detected, the transformer is automatically shut down to prevent a fire from breaking out. The basis for the fire protection is a Buchholz relay. This relay ensures prompt identification of cooling required for components at risk of overheating. The TrafoProtect solution developed by Minimax based on the latest research results, protection aims and testing schemes completes the concept. The special UL-approved nozzles, Viking Model A and Model C-1, achieve an even and consistent distribution of water when activated. In doing so, the system successfully meets the protection aims of "control" and "suppression". At the same time, the consumption of water can be reduced to a level significantly below that of conventional deluge systems. A fire detection system will trigger the extinguishing system.

  6. Waste disposal
    6 Waste disposal

    Protection zone

    Large quantities of different types of packaging waste are often collected in separate recycling and waste collection areas. Cardboard and trash compactors reduce the storage volume. In addition, waste is also stored in containers in outside areas.

    Risks

    • Auto-ignition in case of insufficient ventilation
    • Large quantities of highly flammable organic material
    • Arson in outdoor areas
    • Carelessly discarded cigarette butts

    Fire Protection

    The sprinkler systems used for the protection of buildings effectively combat fires also in the case of burning organic waste and packaging materials. Outdoor areas can be included in the protection range, in which case a dry system or, alternatively, Minimax PipeGuard Antifreeze prevents freezing of the extinguishing water and protects against possible frost damage. If large quantities are stored, a deluge system with open nozzles should rather be selected. This system is triggered by a fire detection system with UniVario industrial smoke detectors.

  7. Kitchens
    7 Kitchens

    Protection zone

    No gastronomy area can do without a kitchen. Food is generally prepared directly on site in kitchens of varying dimensions. This is where foods are prepared, cooked and often kept warm until served.

    Risks

    • Overheated frying and grilling plates
    • Unprofessional operation of appliances
    • Technical defects in electrical appliances
    • High fire load due to large quantities of grease used

    Fire Protection

    The KS 2000 kitchen protection extinguishing system offers ideal fire protection for cooking stations and deep fryers. This system triggers at an incipient outbreak of fire within seconds, and fights even grease fires using the special extinguishing agent Febramax-S. Sprinkler systems protect the building.

  8. Cable ducts
    8 Cable ducts

    Protection zone

    Whether for power supply or data transmission, countless cables are required for the operation and supply of a power station. In order to provide adequate protection, in addition to for aesthetic reasons, cables are distributed via cable channels and organized in cable rooms and galleries.

    Risks

    • Technical defects, such as short circuits
    • Rapid spread of fire

    Fire Protection

    The Minifog ProCon water mist extinguishing system is used in cable ducts as well as in cable rooms and galleries. Designed with impulse nozzles in cable ducts, and with twin hollow core nozzles in cable rooms and galleries, this water mist extinguishing system is particularly notable for its minimal consumption of water. Fire detection and triggering of the water mist extinguishing system in cabling areas is done through fire detection systems with optical smoke detectors. 

  9. Server rooms
    9 Server rooms

    Protection zone

    Server rooms are important, sensitive areas. In these rooms, data of high importance for business operations is stored, managed and exchanged over the network. The irretrievable loss of this data through a fire may have considerable economic consequences for productivity or even the future of a company.

    Risks

    • Overheating of technical equipment
    • Defects such as short circuits
    • Considerable damage even in the case of small fires

    Fire Protection

    For small and medium-sized server rooms, the MX 1230 extinguishing system is the ideal solution. It gives residue-free extinguishing using the innovative Novec™ 1230 extinguishing agents and requires very little space. Oxeo inert gas extinguishing systems are ideal for large server rooms. The MX 1230 extinguishing system and Oxeo inert gas extinguishing systems are triggered, and fires are detected, by a fire detection system using a HELIOS AMX5000 smoke aspirating system.

Downloads

Fire protection solutions for hospitals
Brochures (3.0 mb)